22 changes: 13 additions & 9 deletions README.md
Original file line number Diff line number Diff line change
Expand Up @@ -67,12 +67,18 @@ Staff should begin with First run and Daily workflow. Administrators should also
| Native desktop source version | 1.8.0-1 |
| Candidate hashes | [SHA-256 checksums](https://github.com/townlight/townlight/releases/download/townlight-windows-v1.8.0.1/SHA256SUMS-Windows-1.8.0.1.txt) and [Windows acceptance summary](https://github.com/townlight/townlight/releases/download/townlight-windows-v1.8.0.1/ACCEPTANCE-Windows-1.8.0.1.md) |
| Current owned software license | AGPL-3.0-only |
| Acceptance composition | Fresh Windows x64 profile; inspections-preview; Station configured separately |
| Acceptance composition | Windows x64 fresh install and upgrade from 1.7.2.1. Select the full profile. Station uses separate configuration. |

Start a new installation with an empty database and fresh Windows profile. For an upgrade from Windows 1.7.2.1, keep the existing profile. The approved profile path is `%LOCALAPPDATA%\CivicSuite`. Keep existing profiles and backups.

## First run

**Upgrade from 1.7.2.1.** For the tested upgrade from 1.7.2.1, back up city data and settings, close Townlight, run the signed Windows 1.8.0.1 MSI, and reopen Townlight under the same Windows account with its existing profile. Keep the existing `%LOCALAPPDATA%\CivicSuite` directory. Upgrade paths from versions older than 1.7.2.1 are unverified. Station uses its separately configured service.

### Fresh installation

Run the signed Windows 1.8.0.1 MSI and use an empty database and a new Townlight profile for first run.

1. Download the signed MSI, matching source companion and checksums from the [public Windows release](https://github.com/townlight/townlight/releases/tag/townlight-windows-v1.8.0.1).
2. Verify the MSI hash and Authenticode publisher before installation. See the [Windows acceptance summary](https://github.com/townlight/townlight/releases/download/townlight-windows-v1.8.0.1/ACCEPTANCE-Windows-1.8.0.1.md) for the tested setup.
3. Launch Townlight under the intended named Windows account. Choose the storage folders. Select **Townlight Inspections candidate** (`inspections-preview`) for the bounded desktop composition, including Access and Notice. A narrower default selection will not expose all workspaces.
Expand Down Expand Up @@ -229,7 +235,7 @@ Source contracts: `townlight_core/catalog/__init__.py`, `townlight_core/exemptio

### Runtime and storage

The accepted package targets **Windows x64 fresh installation**. Its native shell uses **Rust 2021, Tauri 2 and Microsoft WebView2**; browser assets are JavaScript built with **Vite 8.1.6**. This describes the native desktop frontend; Station has a separate React operator, specified below or in its product manual. Canonical business workflows use bundled **CPython 3.13.5, FastAPI, Pydantic, SQLAlchemy and Alembic**, with **PostgreSQL 17 / PostGIS** and managed original files. The installed runtime tested here contains FastAPI 0.162.0. Package minimum Python requirements can differ from the bundled executable; the metadata reference preserves both. No stack rewrite is implied by the beta label.
The accepted package supports Windows x64 fresh installation and upgrade from 1.7.2.1. Its native shell uses **Rust 2021, Tauri 2 and Microsoft WebView2**; browser assets are JavaScript built with **Vite 8.1.6**. This describes the native desktop frontend; Station has a separate React operator, specified below or in its product manual. Canonical business workflows use bundled **CPython 3.13.5, FastAPI, Pydantic, SQLAlchemy and Alembic**, with **PostgreSQL 17 / PostGIS** and managed original files. The installed runtime tested here contains FastAPI 0.162.0. Package minimum Python requirements can differ from the bundled executable; the metadata reference preserves both. No stack rewrite is implied by the beta label.

The native transport is fixed to loopback `127.0.0.1:15480`; PostgreSQL uses the configured local runtime port (default `15432`). Optional local model service defaults to `127.0.0.1:15434`. Those are deployment defaults, not internet endpoints. The runtime has health, module and readiness endpoints; readiness is stronger than process existence. The task queue is the existing local Core task infrastructure, not an assertion that a separate Redis service is required for this desktop composition.

Expand Down Expand Up @@ -344,7 +350,7 @@ Use protected local folders, account permissions and credential storage. Never i

Save work and use Core’s canonical **Backup Now** before maintenance. That operation stops writers. Preserve the coherent profile/database/document backup and its receipt, then use **Start** to resume. A source export is not a full backup.

Use **Restore Latest Backup** through the supported controls. If the result says **Restore needs service start**, use **Start**, then **Check**, and reopen a known record. Do not repeat restore merely because services need to start. The fresh-profile acceptance verified that a fulfilled request survived restore and a post-backup marker did not.
Use **Restore Latest Backup** through the supported controls. If the result says **Restore needs service start**, use **Start**, then **Check**, and reopen a known record. Do not repeat restore merely because services need to start. The [Windows 1.6.0.1 Beta 1 fresh-install acceptance](https://github.com/townlight/townlight/releases/tag/townlight-beta-1) verified that a fulfilled request survived restore and a post-backup marker did not.

Keep Station’s dedicated database and media evidence together in its own backup. Core’s native-profile backup must not be assumed to include an external Station data directory. Stop writers during a coordinated backup. Preserve failed media attempts and logs.

Expand All @@ -365,15 +371,13 @@ On failure, record the time, selected composition, component/installer versions

## Verified workflows and limits

The table records selected synthetic workflows from the original [Windows 1.6.0.1 Beta 1](https://github.com/townlight/townlight/releases/tag/townlight-beta-1) Sandbox run. Station’s later delivery has [separate Windows 1.6.0.1 acceptance](https://github.com/townlight/townlight/releases/tag/townlight-beta-1-station-delivery). See the [Windows 1.8.0.1 acceptance summary](https://github.com/townlight/townlight/releases/download/townlight-windows-v1.8.0.1/ACCEPTANCE-Windows-1.8.0.1.md) for the workflows and upgrade path exercised on the current MSI.

| Product | Recorded result | Precisely exercised |
|----|----|----|
| Core | PASS | Normal empty-profile setup; canonical activation; UI-created staff and sign-in; staff denied user administration; coherent backup, mutation, restore, Start/Check and retained/absent record readback. |

These results come from the identified signed candidate’s fresh normal-profile Sandbox exercise: real native IPC/HTTP/PostgreSQL and selected headless controls. All accounts, source bundles and media were synthetic. The guest install/uninstall and recovery passed, and the owned Sandbox stopped. No host installed application or standalone CivicCast was changed. This documentation task reuses those receipts; it does not claim a new software acceptance run.

See the [Windows acceptance summary](https://github.com/townlight/townlight/releases/download/townlight-windows-v1.8.0.1/ACCEPTANCE-Windows-1.8.0.1.md) for this MSI. The historical [evidence index](https://townlight.github.io/reference/sandbox-evidence-index.json) applies to its original build.

The limits remain: actual city field acceptance and equipment/network commissioning; Station automatic provisioning/SCM commissioning; every UI/role combination; field recognition accuracy; and historical in-place upgrades are not certified. They are not five invented feature requirements. Fresh-install controlled beta handoff remains the accepted scope. This package makes no city-deployment, publication or general-availability claim.
The Windows 1.8.0.1 acceptance covers the tested installation paths and selected synthetic workflows, including Boards & Commissions, Contracts, and Procurement. Earlier results apply to their original builds. City field acceptance, physical equipment and network commissioning, Station automatic provisioning, and comprehensive UI and role coverage remain outside the 1.8.0.1 checks.

## Terms of service and license

Expand Down Expand Up @@ -401,7 +405,7 @@ Staff verify the jurisdiction, source currency, permissions, citations and propo

### Beta operation and recovery

Use the identified candidate in its supported fresh-install scope. Preserve backups and original evidence. Test physical equipment and chosen network/service configuration before relying on them. The supplied acceptance describes selected synthetic workflows, not every screen, vendor, field condition or upgrade. Operators decide whether a particular deployment meets their own operational obligations.
Windows 1.8.0.1 was tested for fresh installation and in-place upgrade from 1.7.2.1. Upgrade paths from versions older than 1.7.2.1 are unverified. Station uses its separately configured service. Keep backups and original evidence. Test your physical equipment and network and service configuration before relying on them. See the [acceptance summary](https://github.com/townlight/townlight/releases/download/townlight-windows-v1.8.0.1/ACCEPTANCE-Windows-1.8.0.1.md) for the tested paths.

### Warranty and liability

Expand Down
94 changes: 50 additions & 44 deletions README.txt
Original file line number Diff line number Diff line change
@@ -1,7 +1,7 @@
Windows x64 Beta 1 · MSI 1.8.0.1

The signed Windows x64 beta 1.8.0.1 updates installer metadata while
preserving the accepted signed application/runtime cabinet.
The signed Windows x64 beta 1.8.0.1 adds the three staff workspaces and
automatically refreshes the bundled runtime when upgrading from 1.7.2.1.

- Townlight Core Manual
- Contents
Expand Down Expand Up @@ -71,22 +71,35 @@ included with the same documentation companion.
Beta identity

Identity Value
-------------------------------- -------------------------------------------------------------------------------
-------------------------------- -------------------------------------------------------------------------------------------------------------------
Documentation Townlight Beta 1 naming, Access and Notice candidate
Windows MSI version 1.8.0.1
Windows MSI version 1.8.0.1
Product component townlight-core 1.3.0.dev2
Principal import package townlight_core
Native desktop source version 1.8.0-1
Candidate hashes SHA-256 checksums and Windows acceptance summary
Current owned software license AGPL-3.0-only
Acceptance composition Fresh Windows x64 profile; inspections-preview; Station configured separately
Acceptance composition Windows x64 fresh install and upgrade from 1.7.2.1. Select the full profile. Station uses separate configuration.

Use an empty database and fresh Windows profile. The installer refuses
legacy profile initialization. The approved profile path is
%LOCALAPPDATA%\CivicSuite. Keep existing profiles and backups.
Start a new installation with an empty database and fresh Windows
profile. For an upgrade from Windows 1.7.2.1, keep the existing profile.
The approved profile path is %LOCALAPPDATA%\CivicSuite. Keep existing
profiles and backups.

First run

Upgrade from 1.7.2.1. For the tested upgrade from 1.7.2.1, back up city
data and settings, close Townlight, run the signed Windows 1.8.0.1 MSI,
and reopen Townlight under the same Windows account with its existing
profile. Keep the existing %LOCALAPPDATA%\CivicSuite directory. Upgrade
paths from versions older than 1.7.2.1 are unverified. Station uses its
separately configured service.

Fresh installation

Run the signed Windows 1.8.0.1 MSI and use an empty database and a new
Townlight profile for first run.

1. Download the signed MSI, matching source companion and checksums
from the public Windows release.
2. Verify the MSI hash and Authenticode publisher before installation.
Expand Down Expand Up @@ -326,16 +339,16 @@ Technical specifications

Runtime and storage

The accepted package targets Windows x64 fresh installation. Its native
shell uses Rust 2021, Tauri 2 and Microsoft WebView2; browser assets are
JavaScript built with Vite 8.1.6. This describes the native desktop
frontend; Station has a separate React operator, specified below or in
its product manual. Canonical business workflows use bundled CPython
3.13.5, FastAPI, Pydantic, SQLAlchemy and Alembic, with PostgreSQL 17 /
PostGIS and managed original files. The installed runtime tested here
contains FastAPI 0.162.0. Package minimum Python requirements can differ
from the bundled executable; the metadata reference preserves both. No
stack rewrite is implied by the beta label.
The accepted package supports Windows x64 fresh installation and upgrade
from 1.7.2.1. Its native shell uses Rust 2021, Tauri 2 and Microsoft
WebView2; browser assets are JavaScript built with Vite 8.1.6. This
describes the native desktop frontend; Station has a separate React
operator, specified below or in its product manual. Canonical business
workflows use bundled CPython 3.13.5, FastAPI, Pydantic, SQLAlchemy and
Alembic, with PostgreSQL 17 / PostGIS and managed original files. The
installed runtime tested here contains FastAPI 0.162.0. Package minimum
Python requirements can differ from the bundled executable; the metadata
reference preserves both. No stack rewrite is implied by the beta label.

The native transport is fixed to loopback 127.0.0.1:15480; PostgreSQL
uses the configured local runtime port (default 15432). Optional local
Expand Down Expand Up @@ -549,8 +562,8 @@ a full backup.
Use Restore Latest Backup through the supported controls. If the result
says Restore needs service start, use Start, then Check, and reopen a
known record. Do not repeat restore merely because services need to
start. The fresh-profile acceptance verified that a fulfilled request
survived restore and a post-backup marker did not.
start. The Windows 1.6.0.1 Beta 1 fresh-install acceptance verified that
a fulfilled request survived restore and a post-backup marker did not.

Keep Station’s dedicated database and media evidence together in its own
backup. Core’s native-profile backup must not be assumed to include an
Expand Down Expand Up @@ -579,28 +592,21 @@ Troubleshooting

Verified workflows and limits

The table records selected synthetic workflows from the original Windows
1.6.0.1 Beta 1 Sandbox run. Station’s later delivery has separate
Windows 1.6.0.1 acceptance. See the Windows 1.8.0.1 acceptance summary
for the workflows and upgrade path exercised on the current MSI.

Product Recorded result Precisely exercised
--------- ----------------- --------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
Core PASS Normal empty-profile setup; canonical activation; UI-created staff and sign-in; staff denied user administration; coherent backup, mutation, restore, Start/Check and retained/absent record readback.

These results come from the identified signed candidate’s fresh
normal-profile Sandbox exercise: real native IPC/HTTP/PostgreSQL and
selected headless controls. All accounts, source bundles and media were
synthetic. The guest install/uninstall and recovery passed, and the
owned Sandbox stopped. No host installed application or standalone
CivicCast was changed. This documentation task reuses those receipts; it
does not claim a new software acceptance run.

See the Windows acceptance summary for this MSI. The historical evidence
index applies to its original build.

The limits remain: actual city field acceptance and equipment/network
commissioning; Station automatic provisioning/SCM commissioning; every
UI/role combination; field recognition accuracy; and historical in-place
upgrades are not certified. They are not five invented feature
requirements. Fresh-install controlled beta handoff remains the accepted
scope. This package makes no city-deployment, publication or
general-availability claim.
The Windows 1.8.0.1 acceptance covers the tested installation paths and
selected synthetic workflows, including Boards & Commissions, Contracts,
and Procurement. Earlier results apply to their original builds. City
field acceptance, physical equipment and network commissioning, Station
automatic provisioning, and comprehensive UI and role coverage remain
outside the 1.8.0.1 checks.

Terms of service and license

Expand Down Expand Up @@ -665,12 +671,12 @@ amounts do not become a new authoritative calculation.

Beta operation and recovery

Use the identified candidate in its supported fresh-install scope.
Preserve backups and original evidence. Test physical equipment and
chosen network/service configuration before relying on them. The
supplied acceptance describes selected synthetic workflows, not every
screen, vendor, field condition or upgrade. Operators decide whether a
particular deployment meets their own operational obligations.
Windows 1.8.0.1 was tested for fresh installation and in-place upgrade
from 1.7.2.1. Upgrade paths from versions older than 1.7.2.1 are
unverified. Station uses its separately configured service. Keep backups
and original evidence. Test your physical equipment and network and
service configuration before relying on them. See the acceptance summary
for the tested paths.

Warranty and liability

Expand Down
Binary file modified USER-MANUAL.docx
Binary file not shown.
Loading