Prove Thold alerting and Maint suppression end to end #47
Alerting works with no Thold or Maint change. This issue proves it and documents the limits.
Requirements
REQ-ALERT-010 A Thold threshold on degraded MUST fire when a fixture link drops from 4X to 1X and recover when restored, with no Thold change.
REQ-ALERT-011 A Thold threshold on age MUST fire when sweeps stop.
REQ-ALERT-012 A Thold threshold on a counter rate, such as symbol errors, MUST fire on a fixture error burst and MUST NOT fire on a discontinuity.
REQ-MAINT-001 A Maint device schedule MUST suppress these notifications while measurements continue.
REQ-ALERT-013 Documentation MUST state that Thold durations should be at least one poll interval and that a sweep that falls behind raises age before it changes any other value.
Acceptance criteria
End-to-end test with Thold and Maint at their current releases.