6 changes: 4 additions & 2 deletions .github/workflows/pre-merge.yaml
Original file line number Diff line number Diff line change
Expand Up @@ -25,7 +25,8 @@ jobs:
go-version: ${{ env.GO_VERSION }}
- name: Set list of modules
id: set-modules
run: echo "modules=$(go list -m -json | jq -s '.' | jq -c '[.[].Dir]')" >> $GITHUB_OUTPUT
# The root module and the nested ones, such as scenario/.
run: echo "modules=$(find "$PWD" -name go.mod -not -path '*/bin/*' -printf '%h\n' | sort | jq -R . | jq -sc .)" >> $GITHUB_OUTPUT

golangci-lint:
needs: detect-modules
Expand Down Expand Up @@ -57,7 +58,8 @@ jobs:
with:
go-version: ${{ env.GO_VERSION }}
- name: Run tests
run: go test -v ${{ matrix.modules }}/...
working-directory: ${{ matrix.modules }}
run: go test -v ./...

build-e2e:
# The on-hardware integration harnesses are not run in CI (they need real
Expand Down
3 changes: 2 additions & 1 deletion .github/workflows/release.yaml
Original file line number Diff line number Diff line change
Expand Up @@ -41,7 +41,8 @@ jobs:
with:
go-version-file: go.mod
- name: Run tests
run: go test -v ./...
# Every module, including the nested scenario/ one.
run: make tests

release:
needs: quality-gate
Expand Down
2 changes: 2 additions & 0 deletions Makefile
Original file line number Diff line number Diff line change
Expand Up @@ -16,13 +16,15 @@ E2E_BUILD_ENV := CGO_ENABLED=0 GOOS=$(E2E_GOOS) GOARCH=$(E2E_GOARCH)
lint:
@echo "Linting..."
golangci-lint run -c .golangci.yaml ./...
cd scenario && golangci-lint run -c ../.golangci.yaml ./...
@echo "Lint done"

# TODO
.PHONY: tests
tests:
@echo "Running tests..."
go test -v ./...
cd scenario && go test -v ./...
@echo "Tests done"

# Build the on-hardware integration harnesses as static linux/amd64 binaries
Expand Down
109 changes: 109 additions & 0 deletions scenario/README.md
Original file line number Diff line number Diff line change
@@ -0,0 +1,109 @@
# Hardware scenarios

Replay what happens on a RAID controller, such as a drive failing and being
replaced, from real controller output, and check what raidmgmt reports,
without the hardware.

Scenarios are Gherkin features in [`features/`](features), one per
controller family and story, tagged with the family (`@megaraid`,
`@storcli2`, `@ssacli`). The `Background` names the capture of a real
controller; each `Scenario` plays events on its drives and gives, as a
table, the disks expected:

```gherkin
@megaraid
Feature: MegaRAID disk failure and replacement

Background:
Given the controller captured as "megaraid9560-4hdd"

Scenario: A failed drive does not take the paths of the others
When drive 251:3 fails
Then the drives are reported as:
| slot | status | serial | devicePath | permanentPath |
| 251:1 | Used | SIMD0001000000000000 | /dev/sdl | /dev/disk/by-id/wwn-0x6000… |
| 251:3 | Failed | SIMD0003 | | |
But known bug ARTESCA-17960 reports instead:
| slot | status | serial | devicePath | permanentPath |
| 251:1 | Used | SIMD0001000000000000 | | |
| 251:3 | Failed | SIMD0003 | | |
```

## Steps

| Step | Event |
|---|---|
| `Given the controller captured as "<capture>"` | Start from a capture |
| `drive <slot> fails` / `has failed` | The drive fails; its volume goes offline, no longer a block device |
| `drive <slot> is replaced` / `has been replaced by a drive with serial "<serial>" and WWN "<wwn>"` | Its volume is deleted and a new drive, in no volume, takes the slot |
| `a volume is created` / `has been created on drive <slot>, exposed as "<device>" with WWN "<wwn>"` | The volume the drive had in the capture is created again on it |
| `Then the drives are reported as:` | Check the table: status, serial, and the device and permanent paths of the volume holding each drive. An empty cell is an empty value |
| `But known bug <ticket> reports instead:` | Right after a `Then`: the table reported today because of the bug |

- Each scenario stands alone: it replays its own events on the capture, the
ones it depends on written as `Given` steps.
- Events are written the same for every controller; each backend applies
them as its controller shows them (states, serials, drive groups), as
documented in its package. A backend rejects events in an order that
cannot happen: only a drive in a volume fails, only a failed drive is
replaced, and a volume is created only once the old one is deleted.
- A known bug passes while its table is reported. It fails when the
expected table is reported (the bug is fixed: remove the step) and when
neither is (the behaviour changed).
- Steps are run by [godog](https://github.com/cucumber/godog), strictly: a
step with no definition fails. When a table differs, the error prints the
table reported, ready to paste.

## Where scenarios are played

- `megaraidsim/adapter_test.go` plays every `@megaraid` scenario (storcli64)
through the raidmgmt megaraid adapter of this repository, with
`scenario.Run`.
- `storcli2sim/adapter_test.go` plays every `@storcli2` scenario through the
raidmgmt storcli2 adapter.
- `ssaclisim/adapter_test.go` plays every `@ssacli` scenario (HPE Smart
Array) through the raidmgmt ssacli getters.
- `steps_internal_test.go` checks the steps themselves on the features of
[`testdata/`](testdata), in particular that they fail when they should.

This is a separate module (`github.com/scality/raidmgmt/scenario`), which
uses the raidmgmt code of this repository through a `replace`: godog and
the captures stay out of the dependencies and the downloads of raidmgmt.

## Adding a scenario

Add a `Scenario` to a feature, or a `.feature` file in `features/` tagged
with its controller family, on an existing capture, and run `go test ./...`
in this directory. A new kind of event needs a step in `steps.go` and its
handling in every backend.

## Adding a controller

1. Capture its CLI output on a lab machine, one file per command the adapter
runs, in `<backend>/captures/<name>/`.
2. Write a backend that answers those commands from the capture with the
events applied, as [`megaraidsim`](megaraidsim) does for storcli64, and
gives the host files the adapter checks.
3. Add a test calling `scenario.Run` with the tag of that controller and a
player reporting through its adapter; `scenario.Report` turns what an
adapter reports into the disks of a table.

## Captures

- `megaraidsim/captures/megaraid9560-4hdd`: MegaRAID 9560-8i, SEAGATE
ST18000NM000D drives in enclosure 251, one RAID0 volume each (storcli64
007.1616). Captured with `storcli64 <selector> show all J` on 12 drives,
kept to the first 4 (251:1-4, volumes 239-236) to keep scenarios short.
Serials, WWNs and controller identifiers are replaced by fake ones, also in
the hex inquiry data; keep it so when adding a capture.
- `storcli2sim/captures/storcli2-4hdd`: storcli2 controller, SEAGATE
ST10000NM018B drives in enclosure 306, one RAID0 volume each (storcli2
008.0005). Captured with `storcli2 <selector> show all J` on 24 drives,
kept to the first 4 (306:0-3, volumes 1-4), with the same fake identifiers
(drive serials, WWNs and SAS addresses, volume NAA Ids and serials).
- `ssaclisim/captures/ssacli-4hdd`: HPE Smart Array P816i-a, SAS HDDs each
in its own RAID0 array. Captured with `ssacli controller slot=0 ... show
detail` and `show config`, kept to 4 drives (1I:1:3, 1I:1:4, 2I:2:1,
2I:2:2, logical drives 2-5), with the same fake identifiers (serials,
WWIDs, unique identifiers, controller and host serials). ssacli prints
text: the backend edits the lines of the captured sections.
61 changes: 61 additions & 0 deletions scenario/features/megaraid-disk-failure.feature
Original file line number Diff line number Diff line change
@@ -0,0 +1,61 @@
@megaraid
Feature: MegaRAID disk failure and replacement
A MegaRAID 9560-8i with HDDs in enclosure 251, each in its own RAID0
volume, as ARTESCA deploys them. Drive 251:3 fails, is replaced, then gets a
new volume (RD-2154, ARTESCA-17960).

The capture is real storcli output of a lab node while all its drives
were healthy, kept to its first 4 drives, with serials and WWNs replaced by
fake ones.

Each table lists, per drive, what raidmgmt must report: the drive, and
the paths of the volume holding it.

Background:
Given the controller captured as "megaraid9560-4hdd"

Scenario: All drives are healthy
Then the drives are reported as:
| slot | status | serial | devicePath | permanentPath |
| 251:1 | Used | SIMD0001000000000000 | /dev/sdl | /dev/disk/by-id/wwn-0x600062b2000000000000000000000239 |
| 251:2 | Used | SIMD0002000000000000 | /dev/sdk | /dev/disk/by-id/wwn-0x600062b2000000000000000000000238 |
| 251:3 | Used | SIMD0003000000000000 | /dev/sdj | /dev/disk/by-id/wwn-0x600062b2000000000000000000000237 |
| 251:4 | Used | SIMD0004000000000000 | /dev/sdi | /dev/disk/by-id/wwn-0x600062b2000000000000000000000236 |

Scenario: A failed drive does not take the paths of the others
When drive 251:3 fails
Then the drives are reported as:
| slot | status | serial | devicePath | permanentPath |
| 251:1 | Used | SIMD0001000000000000 | /dev/sdl | /dev/disk/by-id/wwn-0x600062b2000000000000000000000239 |
| 251:2 | Used | SIMD0002000000000000 | /dev/sdk | /dev/disk/by-id/wwn-0x600062b2000000000000000000000238 |
| 251:3 | Failed | SIMD0003 | | |
| 251:4 | Used | SIMD0004000000000000 | /dev/sdi | /dev/disk/by-id/wwn-0x600062b2000000000000000000000236 |
# The offline volume has no by-id link: its path cannot be resolved, which
# fails the listing of all the volumes of the controller.
But known bug ARTESCA-17960 reports instead:
| slot | status | serial | devicePath | permanentPath |
| 251:1 | Used | SIMD0001000000000000 | | |
| 251:2 | Used | SIMD0002000000000000 | | |
| 251:3 | Failed | SIMD0003 | | |
| 251:4 | Used | SIMD0004000000000000 | | |

Scenario: A replacement drive is reported as a new, available drive
Given drive 251:3 has failed
When drive 251:3 is replaced by a drive with serial "SIMD0013000000000000" and WWN "5000C50000000013"
Then the drives are reported as:
| slot | status | serial | devicePath | permanentPath |
| 251:1 | Used | SIMD0001000000000000 | /dev/sdl | /dev/disk/by-id/wwn-0x600062b2000000000000000000000239 |
| 251:2 | Used | SIMD0002000000000000 | /dev/sdk | /dev/disk/by-id/wwn-0x600062b2000000000000000000000238 |
| 251:3 | UnassignedGood | SIMD0013000000000000 | | |
| 251:4 | Used | SIMD0004000000000000 | /dev/sdi | /dev/disk/by-id/wwn-0x600062b2000000000000000000000236 |

Scenario: A replacement drive gets the paths of its new volume
Given drive 251:3 has failed
And drive 251:3 has been replaced by a drive with serial "SIMD0013000000000000" and WWN "5000C50000000013"
When a volume is created on drive 251:3, exposed as "/dev/sdm" with WWN "600062b2000000000000000000001237"
Then the drives are reported as:
| slot | status | serial | devicePath | permanentPath |
| 251:1 | Used | SIMD0001000000000000 | /dev/sdl | /dev/disk/by-id/wwn-0x600062b2000000000000000000000239 |
| 251:2 | Used | SIMD0002000000000000 | /dev/sdk | /dev/disk/by-id/wwn-0x600062b2000000000000000000000238 |
| 251:3 | Used | SIMD0013000000000000 | /dev/sdm | /dev/disk/by-id/wwn-0x600062b2000000000000000000001237 |
| 251:4 | Used | SIMD0004000000000000 | /dev/sdi | /dev/disk/by-id/wwn-0x600062b2000000000000000000000236 |
51 changes: 51 additions & 0 deletions scenario/features/ssacli-disk-failure.feature
Original file line number Diff line number Diff line change
@@ -0,0 +1,51 @@
@ssacli
Feature: ssacli disk failure and replacement
The ssacli counterpart of megaraid-disk-failure: an HPE Smart Array
P816i-a with HDDs, each in its own RAID0 array, as ARTESCA deploys them.
Drive 1I:1:4 (array C, logical drive 3) fails, is replaced, then gets a new
array (ARTESCA-17960).

The capture is real ssacli output of a lab node while all its drives were
healthy, kept to 4 drives, with serials, WWIDs and identifiers replaced by
fake ones. ssacli getters report no permanent path.

Background:
Given the controller captured as "ssacli-4hdd"

Scenario: All drives are healthy
Then the drives are reported as:
| slot | status | serial | devicePath | permanentPath |
| 1I:1:3 | Used | SIMH0001 | /dev/sdd | |
| 1I:1:4 | Used | SIMH0002 | /dev/sde | |
| 2I:2:1 | Used | SIMH0003 | /dev/sdf | |
| 2I:2:2 | Used | SIMH0004 | /dev/sdg | |

Scenario: A failed drive does not take the paths of the others
When drive 1I:1:4 fails
Then the drives are reported as:
| slot | status | serial | devicePath | permanentPath |
| 1I:1:3 | Used | SIMH0001 | /dev/sdd | |
| 1I:1:4 | Failed | SIMH0002 | | |
| 2I:2:1 | Used | SIMH0003 | /dev/sdf | |
| 2I:2:2 | Used | SIMH0004 | /dev/sdg | |

Scenario: A replacement drive is reported as a new, available drive
Given drive 1I:1:4 has failed
When drive 1I:1:4 is replaced by a drive with serial "SIMH0013" and WWN "5000C50030000013"
Then the drives are reported as:
| slot | status | serial | devicePath | permanentPath |
| 1I:1:3 | Used | SIMH0001 | /dev/sdd | |
| 1I:1:4 | UnassignedGood | SIMH0013 | | |
| 2I:2:1 | Used | SIMH0003 | /dev/sdf | |
| 2I:2:2 | Used | SIMH0004 | /dev/sdg | |

Scenario: A replacement drive gets the paths of its new array
Given drive 1I:1:4 has failed
And drive 1I:1:4 has been replaced by a drive with serial "SIMH0013" and WWN "5000C50030000013"
When a volume is created on drive 1I:1:4, exposed as "/dev/sdh" with WWN "600508B1000000000000000000001003"
Then the drives are reported as:
| slot | status | serial | devicePath | permanentPath |
| 1I:1:3 | Used | SIMH0001 | /dev/sdd | |
| 1I:1:4 | Used | SIMH0013 | /dev/sdh | |
| 2I:2:1 | Used | SIMH0003 | /dev/sdf | |
| 2I:2:2 | Used | SIMH0004 | /dev/sdg | |
59 changes: 59 additions & 0 deletions scenario/features/storcli2-disk-failure.feature
Original file line number Diff line number Diff line change
@@ -0,0 +1,59 @@
@storcli2
Feature: storcli2 disk failure and replacement
The storcli2 counterpart of megaraid-disk-failure: a controller driven by
storcli2 with HDDs in enclosure 306, each in its own RAID0 volume, as
ARTESCA deploys them. Drive 306:2 fails, is replaced, then gets a new
volume (ARTESCA-17960).

The capture is real storcli2 output of a lab node while all its drives
were healthy, kept to its first 4 drives, with serials, WWNs and volume
identifiers replaced by fake ones.

Background:
Given the controller captured as "storcli2-4hdd"

Scenario: All drives are healthy
Then the drives are reported as:
| slot | status | serial | devicePath | permanentPath |
| 306:0 | Used | SIMD2001000000000000 | /dev/sdb | /dev/disk/by-id/wwn-0x600062b2000000000000000000000001 |
| 306:1 | Used | SIMD2002000000000000 | /dev/sdc | /dev/disk/by-id/wwn-0x600062b2000000000000000000000002 |
| 306:2 | Used | SIMD2003000000000000 | /dev/sdd | /dev/disk/by-id/wwn-0x600062b2000000000000000000000003 |
| 306:3 | Used | SIMD2004000000000000 | /dev/sde | /dev/disk/by-id/wwn-0x600062b2000000000000000000000004 |

Scenario: A failed drive does not take the paths of the others
When drive 306:2 fails
Then the drives are reported as:
| slot | status | serial | devicePath | permanentPath |
| 306:0 | Used | SIMD2001000000000000 | /dev/sdb | /dev/disk/by-id/wwn-0x600062b2000000000000000000000001 |
| 306:1 | Used | SIMD2002000000000000 | /dev/sdc | /dev/disk/by-id/wwn-0x600062b2000000000000000000000002 |
| 306:2 | Failed | SIMD2003000000000000 | | |
| 306:3 | Used | SIMD2004000000000000 | /dev/sde | /dev/disk/by-id/wwn-0x600062b2000000000000000000000004 |
# The permanent path of the offline volume is still built from its NAA
# Id, although the volume has no block device and no by-id link.
But known bug ARTESCA-17960 reports instead:
| slot | status | serial | devicePath | permanentPath |
| 306:0 | Used | SIMD2001000000000000 | /dev/sdb | /dev/disk/by-id/wwn-0x600062b2000000000000000000000001 |
| 306:1 | Used | SIMD2002000000000000 | /dev/sdc | /dev/disk/by-id/wwn-0x600062b2000000000000000000000002 |
| 306:2 | Failed | SIMD2003000000000000 | | /dev/disk/by-id/wwn-0x600062b2000000000000000000000003 |
| 306:3 | Used | SIMD2004000000000000 | /dev/sde | /dev/disk/by-id/wwn-0x600062b2000000000000000000000004 |

Scenario: A replacement drive is reported as a new, available drive
Given drive 306:2 has failed
When drive 306:2 is replaced by a drive with serial "SIMD2013000000000000" and WWN "5000C50020000013"
Then the drives are reported as:
| slot | status | serial | devicePath | permanentPath |
| 306:0 | Used | SIMD2001000000000000 | /dev/sdb | /dev/disk/by-id/wwn-0x600062b2000000000000000000000001 |
| 306:1 | Used | SIMD2002000000000000 | /dev/sdc | /dev/disk/by-id/wwn-0x600062b2000000000000000000000002 |
| 306:2 | UnassignedGood | SIMD2013000000000000 | | |
| 306:3 | Used | SIMD2004000000000000 | /dev/sde | /dev/disk/by-id/wwn-0x600062b2000000000000000000000004 |

Scenario: A replacement drive gets the paths of its new volume
Given drive 306:2 has failed
And drive 306:2 has been replaced by a drive with serial "SIMD2013000000000000" and WWN "5000C50020000013"
When a volume is created on drive 306:2, exposed as "/dev/sdf" with WWN "600062b2000000000000000000001003"
Then the drives are reported as:
| slot | status | serial | devicePath | permanentPath |
| 306:0 | Used | SIMD2001000000000000 | /dev/sdb | /dev/disk/by-id/wwn-0x600062b2000000000000000000000001 |
| 306:1 | Used | SIMD2002000000000000 | /dev/sdc | /dev/disk/by-id/wwn-0x600062b2000000000000000000000002 |
| 306:2 | Used | SIMD2013000000000000 | /dev/sdf | /dev/disk/by-id/wwn-0x600062b2000000000000000000001003 |
| 306:3 | Used | SIMD2004000000000000 | /dev/sde | /dev/disk/by-id/wwn-0x600062b2000000000000000000000004 |
27 changes: 27 additions & 0 deletions scenario/go.mod
Original file line number Diff line number Diff line change
@@ -0,0 +1,27 @@
module github.com/scality/raidmgmt/scenario

go 1.25.6

require (
github.com/cucumber/godog v0.16.0
github.com/pkg/errors v0.9.1
github.com/scality/raidmgmt v0.14.0
github.com/stretchr/testify v1.11.1
)

require (
github.com/cucumber/gherkin/go/v42 v42.0.0 // indirect
github.com/cucumber/messages/go/v34 v34.2.0 // indirect
github.com/davecgh/go-spew v1.1.2-0.20180830191138-d8f796af33cc // indirect
github.com/google/uuid v1.6.0 // indirect
github.com/hashicorp/go-immutable-radix v1.3.1 // indirect
github.com/hashicorp/go-memdb v1.3.5 // indirect
github.com/hashicorp/golang-lru v0.5.4 // indirect
github.com/kr/pretty v0.3.1 // indirect
github.com/pmezard/go-difflib v1.0.1-0.20181226105442-5d4384ee4fb2 // indirect
github.com/spf13/pflag v1.0.10 // indirect
gopkg.in/yaml.v3 v3.0.1 // indirect
)

// Play the scenarios on the adapters of this repository.
replace github.com/scality/raidmgmt => ../
Loading
Loading