MaRCoS (MAgnetic Resonance COntrol System) is an open-source initiative developed by an international community of low-field MRI researchers. It serves as an electronic control system for magnetic resonance imaging (MRI) devices, handling pulse sequences, signal detection, and processing.
Please see the MaRCoS Wiki for more detailed technical information, examples and tutorials/setup guides.
- Inexpensive: MaRCoS provides a cost-effective solution for MRI device control.
- Cycle-Accurate Sequences: Capable of handling cycle-accurate sequences without hard length limitations.
- Rapid Event Bursts: Supports rapid bursts of events for versatile MRI applications.
- Arbitrary Waveforms: Can handle arbitrary waveforms for flexible imaging techniques.
- Adaptable: Readily adapted to meet the requirements of academic and private institutions.
MaRCoS consists of three main components:
- Hardware: MaRCoS runs on a Red Pitaya SDRLab 122–16, a commercial board featuring two analog inputs for digitizing received data and two analog outputs for generating RF transmit waveforms. It interfaces with either a GPA-FHDO or an OCRA1 four-channel gradient board.
- Firmware: MaRCoS firmware, that operates on FPGA hardware, manages real-time data streaming, synchronization, and controls various aspects, including transmit, gradient, digital I/O, and ADC data acquisition.
- Software: MaRCoS can be controled at high level from a client PC through Python scripts, Pulseq/PyPulseq, or by the dedicated MaRCoS Graphical Environment (MaRGE). MaRGE is able to interface with RFAutoMaTE (Radio-Frequency Automatic Matching and Tuning Equiment).
Guallart‐Naval, T., O’Reilly, T., Algarín, J. M., Pellicer‐Guridi, R., Vives‐Gilabert, Y., Craven‐Brightman, L., Negnevitsky, V., Menküc, B., Galve, F., Stockmann, J. P., Webb, A., & Alonso, J. (2022). Benchmarking the performance of a low‐cost magnetic resonance control system at multiple sites in the open MaRCoS community. NMR in Biomedicine, 36(1), 1–13. https://doi.org/10.1002/nbm.4825
Negnevitsky, V., Vives-gilabert, Y., Algarín, J. M., Craven-Brightman, L., Pellicer-guridi, R., O'Reilly, T., Stockmann, J. P., Webb, A., Alonso, J., & Menküc, B. (2023). MaRCoS, an open-source electronic control system for low-field MRI. Journal of Magnetic Resonance, 350, 107424. https://doi.org/10.1016/j.jmr.2023.107424
Algarín, J. M., Guallart-Naval, T., Borreguero, J., Galve, F., & Alonso, J. (2024). MaRGE: A graphical environment for MaRCoS. Journal of Magnetic Resonance, 361, 107662. https://doi.org/10.1016/j.jmr.2024.107662
Wang, H., Lou, F., Huang, Y., Gao, Y., & Zhang, X. (2024). Function Extension and Implementation of MaRCoS in Low-, Mid-, and High-Field MRI Systems: A Technical Report. https://doi.org/10.36227/techrxiv.172226905.56017383/v1
We express our gratitude to the international community of low-field MRI researchers for their contributions to the development of MaRCoS, including: Tom O'Reilly and Andrew Webb from the Department of Radiology, Leiden University Medical Center, Leiden, The Netherlands; Benjamin Menküc from University of Applied Sciences and Arts Dortmund, Germany; Lincoln Craven-Brightman and Jason P. Stockmann from Massachusetts General Hospital (MGH), A. A. Martinos Center for Biomedical Imaging, Charlestown, MA, USA. Also a special aknoledgment to Thomas Witzel from MGH for developing OCRA, the predecessor of MaRCoS.
Thank you for being a part of the MaRCoS community!