Skip to content

Fix pk.calc.ceoi() for intervals with more than one dose row (#695) - #734

Closed
PavanLomati wants to merge 1 commit into
humanpred:mainfrom
PavanLomati:fix/695-ceoi-multiple-dose-rows
Closed

PavanLomati wants to merge 1 commit into
humanpred:mainfrom
PavanLomati:fix/695-ceoi-multiple-dose-rows

Conversation

@PavanLomati

Copy link
Copy Markdown
Contributor

pk.calc.ceoi() assumed a scalar duration.dose, so an interval with two infusion rows stopped pk.nca() with "the condition has length > 1".

  • Add a time.dose argument so the end of infusion is located as max(time.dose + duration.dose) among doses with duration.dose > 0. Bolus rows (zero or missing duration) are ignored, and infusions separated by a gap use the end of the last infusion.
  • Return NA with an exclude reason instead of a bare NA when there is no infusion, or no non-missing concentration at the end of the infusion.
  • Error on a negative duration.dose instead of treating it as no infusion.
  • Match the sample time with a small tolerance so sums like 0.1 + 0.2 still find a sample at 0.3.
  • ceoi now reports requires_dose_time = TRUE, so update the check.intervals expectation.

Tests cover contiguous segments, a single infusion, a late-start infusion, bolus plus infusion, gaps, unsampled and missing end concentrations, invalid durations, and an end-to-end pk.nca() run.

…ed#695)

pk.calc.ceoi() assumed a scalar duration.dose, so an interval with two
infusion rows stopped pk.nca() with "the condition has length > 1".

- Add a time.dose argument so the end of infusion is located as
  max(time.dose + duration.dose) among doses with duration.dose > 0.
  Bolus rows (zero or missing duration) are ignored, and infusions
  separated by a gap use the end of the last infusion.
- Return NA with an exclude reason instead of a bare NA when there is no
  infusion, or no non-missing concentration at the end of the infusion.
- Error on a negative duration.dose instead of treating it as no
  infusion.
- Match the sample time with a small tolerance so sums like 0.1 + 0.2
  still find a sample at 0.3.
- ceoi now reports requires_dose_time = TRUE, so update the
  check.intervals expectation.

Tests cover contiguous segments, a single infusion, a late-start
infusion, bolus plus infusion, gaps, unsampled and missing end
concentrations, invalid durations, and an end-to-end pk.nca() run.
@billdenney

Copy link
Copy Markdown
Member

I think that multiple Ceoi measures within a period are not expected and would need to be handled as separate intervals.

But, a duration should be validated to be non-negative (zero or greater). Can you please add that validation in a different PR?

@billdenney billdenney closed this Nov 25, 2026
Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment