This is a project for EGR 101 at Duke University. The goal of this project is to track temperature in sample transport conditions in Uganda.
Open arduino/temp-display-pipeline/temp-display-pipeline.ino in the Arduino IDE.
Select Raspberry Pi Pico from Earle Philhower's Raspberry Pi Pico/RP2040
board package (rp2040:rp2040:rpipico). This sketch uses the Arduino-Pico core,
including its configurable I2C pins.
This combines the DS18B20 reader from test-temp and the 20x4 I2C LCD from
test-display with the range timers from sd-display-pipeline. It needs no SD
card or SD library. Install OneWire, DallasTemperature, and
LiquidCrystal_I2C (the version with lcd.init()).
The first reading appears at startup; a new reading and display refresh follow every 1 second. Each temperature conversion takes up to about 750 ms. Serial output uses 9600 baud.
Wiring defaults:
| Connection | Raspberry Pi Pico |
|---|---|
| DS18B20 data | GP22 (physical pin 29), matching test-temp |
| DS18B20 VDD | 3V3(OUT) (physical pin 36) |
| DS18B20 GND | GND (for example physical pin 38) |
| LCD SDA | GP4 (physical pin 6) |
| LCD SCL | GP5 (physical pin 7) |
Use a 4.7 kOhm pull-up from sensor data to 3V3(OUT) and a common ground.
The sketch expects a powered DS18B20, rather than parasite power.
Keep Pico I2C signals at 3.3 V using a level shifter
if the LCD backpack pulls them up to 5 V. The LCD address is 0x27.
The 20x4 display uses this layout (| represents a solid block divider):
MIN xx.x°|CURR xx.x°
MAX xx.x°|AVG xx.x°
<2 OR >8 HH:MM:SS
TOTAL HH:MM:SS
Temperatures are in Celsius. MIN, MAX, and AVG track all valid readings since
startup; AVG is their arithmetic mean. Temperature fields are right-aligned,
show one decimal place, and display #### when a rounded value cannot fit in
four characters, or ---- before any valid reading. The third row shows
cumulative time strictly below 2°C or above 8°C; exactly 2°C and 8°C are
within range. Each interval uses its preceding temperature reading. The last
row shows total elapsed time since the first reading. A sensor failure displays
ERR in the CURR field and preserves the statistics; intervals touching a failed
reading are excluded from the outside-range timer. After a failed reading, the
sketch rescans for the sensor at the next one-second update, including when it
was absent at startup.
Serial diagnostics report the raw failed reading, OneWire presence on GP22,
and the sensor count after each scan. A NO presence result means no presence
pulse was detected; YES with failed readings can indicate corrupted data or
unstable sensor power. Neither message alone identifies the faulty component.
Durations display as HH:MM:SS and stop displaying increases at 99:59:59.
All timers live in RAM and reset when the board restarts.