Plot

A live graph of the numbers a pane prints, for ADC readings, control loops, sensor values. Each line is one sample; its fields, split by a separator, are the channels.

0,27200,1000,305,0,0      → 6 channels
0|2323|12312|232          → 4 channels
kanal,adc,pid,a           → channel names
bla bla bla               → skipped (still shown in the terminal)

Open it with the Plot button in the bottom right corner of the terminal (it shows while the pointer is over the terminal), Ctrl+Shift+G or menu → Plot Values. The pane splits: graph above, terminal below (drag the handle between them). The button is highlighted while the plot is shown; it and the same keys close it. It works in every pane: serial, TCP, telnet, SSH, shell.

Plot of four channels above a serial pane

Lines

Rule Detail
Separator Auto: the first of , `
Numbers 12, -3.5, 1e3, 0x1F
Fields that are not numbers Leave a gap in that channel
A line with no numbers Skipped; if it has several fields, they become the channel names (kanal,adc,pid)
A line with one number One channel
Trailing separator 1,2,3, is three values
Channels Up to 32

Lines read together (e.g. 50 lines in one serial read) are spread evenly over the time since the previous read, so a steady sample rate draws as one.

Controls

Control Effect
Separator Auto or a fixed one
Span Last 1, 5, 10, 30 or 60 seconds, or the last 200, 1000 or 5000 samples
Charts 1 chart; 2 side by side or stacked; 3 as two above one or two beside one; 4 as 2×2. Drag the gaps between charts to resize them
Split One chart per channel (up to four; more channels share them in turn)
Link Zoom and move the time axis of all charts together
Lock Y Keeps the current Y range of every chart (otherwise it follows the shown values)
Pause Freezes the view; samples are still kept. Unpausing goes back to the live view
Names… Channel names, comma separated
⌫ Clears the samples
CSV Saves all kept samples as CSV (time_s,sample,<names>)
PNG Saves all charts as one PNG image

Charts and channels

Each channel is drawn in one chart: pick it with the 1–4 selector next to the channel in the legend (shown when there is more than one chart). Pause and the span apply to all charts; zoom, pan and Lock Y work per chart, and with Link the time axis is shared.

The charts setup (layout, which chart each channel is in, Link and the thresholds) is remembered per session title in ~/.local/state/termvisor/plots.json and comes back the next time the plot of that session is opened.

Right-click menu of a chart

Entry Effect
Cursor A Here / Cursor B Here A dashed vertical line at the pointer, in every chart. With both set, the line under the legend shows Δt between them and the change of every channel (values of the samples nearest to A and B)
Clear Cursors Removes both
Threshold Here A dashed red line at the value under the pointer; the area above it is tinted. While the newest value of a channel in the chart is at or above it, the chart frame turns red
Clear Threshold Removes it
Save Chart as PNG… That chart alone

Cursors are positions in time (or sample number): in the live view they move left with the data, so pause first to measure.

Zoom and pan

Each chart zooms and moves on its own (all together with Link).

Mouse Effect
Wheel Zoom in or out around the pointer on both axes; the point under the pointer stays put. The view freezes and Lock Y turns on
Shift + wheel Zoom the time (or sample) axis only
Ctrl + wheel Zoom the Y axis only
Drag Move the view: left/right in time (the view freezes), up/down in value (Lock Y turns on)
Double-click Back to the live view with an automatic Y axis

While frozen, new samples are still collected; nothing is lost. The line under the plot tells how much is shown.

The legend has a checkbox per channel to hide or show it, its value (the latest one, or the one under the mouse pointer; a vertical line marks the spot) and the minimum, maximum and mean of what its chart shows. The title shows the sample rate, channel count and samples kept (at most 200000).

Drawing runs about 30 times a second whatever the sample rate; dense data is reduced to the minimum and maximum per pixel column.