SensorNetPro hardware

Status

Not started. The KiCad project (SensorNetPro.kicad_pro) has been created, but the schematic and PCB are empty. Until it is designed, build the circuit below by hand on either supported board.

The plan is a carrier board for the Olimex ESP32-POE or the WT32-ETH01, with sensor connectors, a button and status LEDs. The WT32-ETH01 pin map in platformio.ini is provisional and may change with the PCB.

Circuit

The firmware expects:

Function Signal Wiring
1-wire sensor bus ONE_WIRE_BUS DS18B20 DQ lines in parallel, with one 4.7 kΩ pull-up to 3.3 V for the whole bus. Power the sensors from 3.3 V and ground (parasite power also works)
Button KEY_RESET Active low: a push button to ground, with a 10 kΩ pull-up to 3.3 V. The firmware enables no internal pull-up, and the input-only pins (34–39) have none
Error LED ERROR_LED Active high: GPIO → resistor (about 330 Ω–1 kΩ) → LED → ground
Status LED STATUS_LED As above. Flashes once a second while running
Network LED WIFI_LED As above. On while Ethernet or Wi-Fi is connected

Pins

Signal Olimex ESP32-POE WT32-ETH01 (provisional)
ONE_WIRE_BUS GPIO4 GPIO4
KEY_RESET GPIO34 (the on-board BUT1, already pulled up) GPIO39 (needs the external pull-up and button)
ERROR_LED GPIO14 GPIO14
STATUS_LED GPIO15 GPIO2
WIFI_LED GPIO16 GPIO15

Notes:

  • The Ethernet PHY pins are fixed by each board and set by its PlatformIO board variant. Don't use them: on the ESP32-POE that includes GPIO12 (PHY power) and GPIO17 (PHY clock), and on the WT32-ETH01 GPIO0 (PHY clock) and GPIO16 (PHY oscillator enable).
  • GPIO2 and GPIO15 are strapping pins. An LED with its resistor to ground keeps them low at reset, which is safe for normal booting.
  • WROVER-based ESP32-POE variants use GPIO16 for PSRAM, so WIFI_LED would need another pin on those.