<!doctype html><html lang="en"><head><meta charset="utf-8"><meta name="viewport" content="width=device-width,initial-scale=1"><title>Node-RED dashboards, trends and warnings — RayWn2App</title><link rel="stylesheet" href="site.css"><script defer src="search-data.js"></script><script defer src="site.js"></script></head><body><a class="skip" href="#article">Skip to article</a><header><a href="index.html">RF StateSide · RayWn2App Help</a><button id="contents" aria-expanded="false" aria-controls="navigation">Contents</button></header><aside id="navigation"><label for="search">Search the guide</label><input id="search" type="search" placeholder="Try: layout, SWR, Hamlib"><div id="results" aria-live="polite"></div><nav aria-label="Help topics"><section><h2>Start here</h2><a href="index.html">Welcome to RayWn2App Help</a><a href="quick-start.html">First station connection</a><a href="menus.html">Main window, menus and shortcuts</a><a href="station-identity.html">Callsign, location and shortcuts</a><a href="hardware.html">Preparing your WN-2 station</a></section><section><h2>Installation and operating systems</h2><a href="platforms.html">Installing and opening RayWn2App</a><a href="platform-windows.html">RayWn2App on Windows</a><a href="platform-ubuntu.html">RayWn2App on Ubuntu Linux</a><a href="platform-raspberry-pi.html">RayWn2App on Raspberry Pi</a><a href="platform-macos.html">RayWn2App on macOS</a></section><section><h2>Devices and measurements</h2><a href="connections.html">D2XX, VCP and multiple WN-2 devices</a><a href="device-settings.html">Device Settings: where to start</a><a href="recovery.html">Automatic connection recovery and USB controls</a><a href="rf-measurements.html">Power, SWR and Return Loss</a><a href="couplers.html">Couplers, profiles and hardware LCD ranges</a><a href="reference-calibration.html">User reference-matching calibration</a><a href="auxiliary.html">DC and analog inputs</a><a href="temperature.html">LM35 and LM34 temperature instruments</a><a href="digital-io.html">Digital inputs and latched or momentary outputs</a></section><section><h2>Layout</h2><a href="layouts.html">Layouts, groups and templates</a><a href="layout-mode.html">Layout Edit Mode: arranging your station</a></section><section><h2>Dashboard and instruments</h2><a href="instruments.html">Instrument selection and properties</a><a href="analog-meters.html">Analog and cross-needle meters</a><a href="meter-dynamics.html">Auto range, peak hold and markers</a><a href="floating-panels.html">Compact Station Panel and enlarged meters</a><a href="appearance.html">Themes, scale, colors and visibility</a></section><section><h2>Capture and analysis</h2><a href="scope.html">Scope, Mini-Scope and capture lifecycle</a><a href="scope-units.html">Scope timebase, voltage, Vpp and clipping</a><a href="spectrum.html">Envelope Spectrum and modulation bands</a><a href="plot-exports.html">Editable plot titles and PNG exports</a><a href="rf-history.html">RF History and Amplifier Analysis</a><a href="amplifier-gain.html">System and Module Gain instruments</a><a href="recording.html">Timed recording, RF/DC energy and charge</a></section><section><h2>SWR sweeps</h2><a href="manual-sweep.html">Manual SWR sweeps</a><a href="rig-sweep.html">Rig-assisted sweeps and Hamlib setup</a><a href="comparison-curves.html">Multi-channel sweeps and comparison curves</a></section><section><h2>Protection and notifications</h2><a href="swr-protection.html">SWR protection, trips and manual reset</a><a href="smart-reset.html">Smart Reset and protection restoration</a><a href="overdrive.html">Overdrive warnings and hardware limits</a><a href="email.html">Email setup, rules and configuration transfer</a></section><section><h2>Audio</h2><a href="tones.html">Tone generator, pulses and analyzer coordination</a><a href="spoken-readings.html">Audible SWR tuning and spoken readings</a><a href="audio-messages.html">Stored messages, recording and global hotkeys</a></section><section><h2>Accessories and integration</h2><a href="antenna-switch.html">Antenna switch panel and band codes</a><a href="rotators.html">Rotator control availability</a><a href="mqtt.html">MQTT telemetry, credentials and startup</a><a href="node-red.html">Node-RED dashboards, trends and warnings</a><a href="thetis.html">Direct Thetis telemetry</a><a href="remote-access.html">Remote station viewing</a></section><section><h2>Diagnostics and reference</h2><a href="emulator.html">Raw Data Emulator and multiple instances</a><a href="packet-monitor.html">Packet Monitor and traffic diagnostics</a><a href="application-log.html">Application Log and troubleshooting</a><a href="about.html">About, licensing and Help scope</a></section></nav></aside><main id="article">
<h1>Node-RED dashboards, trends and warnings</h1>
<p><b>On this page</b></p><ul><li><a href="#what-node-red-does">What Node-RED does</a></li><li><a href="#station-dashboard">Station dashboard</a></li><li><a href="#station-health-warnings">Station-health warnings</a></li><li><a href="#trends-and-event-history">Trends and event history</a></li><li><a href="#compatibility-sample">Compatibility sample</a></li><li><a href="#troubleshooting">Troubleshooting</a></li></ul><h2 id="what-node-red-does">What Node-RED does</h2>
<p>Node-RED runs on a station computer and can display readings received through your MQTT broker. A flow is a saved arrangement of steps that receives, processes and displays messages. The sample flows are optional; local RayWn2App operation does not depend on them. Have Node-RED and the broker configured before importing the supplied RayWn2App examples. Preserve existing flows and enter your own broker/security settings. Do not expose an unprotected station dashboard to the Internet.</p>
<h2 id="station-dashboard">Station dashboard</h2>
<p>Open the configured Node-RED address followed by <b>/station</b> in your browser. Each device card identifies its source, physical/simulated state, readings and freshness. Check the identity before comparing it with the main application. <b>UNAVAILABLE / STALE</b> means the card has no current valid data. It is not zero RF. <b>Clear unavailable devices</b> hides those cards while keeping live devices. Repeated unavailable messages should not immediately recreate a cleared card; it returns when usable live data returns.</p>
<h2 id="station-health-warnings">Station-health warnings</h2>
<p>The dashboard can display the published station-health information and its configured warning rules. Review the device, condition and timestamp. Acknowledging a dashboard warning does not reset the WN-2 relay or correct the station condition. Rules and display state are separate from RayWn2App's native email and SWR protection settings. Keep the distinction clear when configuring alerts.</p>
<h2 id="trends-and-event-history">Trends and event history</h2>
<p>From /station, open <b>Measurement trends and station events</b>, or <b>/station/history</b>. Select the publisher/device stream and channel. The view plots recent RF/DC readings and shows observed station events. Missing data breaks traces instead of drawing a false zero. The history is bounded and is not a permanent station log. Export selected history as JSON or measurements as CSV before restarting or redeploying the flow. Clear selected history affects that stream's history, not live device control.</p>
<h2 id="compatibility-sample">Compatibility sample</h2>
<p>The optional compatibility adapter translates a selected source to the message format expected by WaveNode-to-MQTT consumers. Dave's original dashboard is a separate third-party example. The RayWn2App-compatible sample adds clear unavailable/stale indications; its page is <b>/wavenode-sample</b>. Choose the intended publisher, WN-2 and channel mapping. Do not merge multiple devices into one unidentified legacy stream. Preserve the native /station dashboard when adding a compatibility example.</p>
<h2 id="troubleshooting">Troubleshooting</h2>
<p>First check that RayWn2App reports publishing active. Then check broker connection/security and the flow's selected source. A working browser page does not prove new MQTT messages are arriving. Confirm timestamps and status before using a reading. These dashboards monitor data; the supplied flows do not provide WN-2 hardware control.</p>
<hr><p><a href="index.html">Help home</a> · RF StateSide · RayWn2App operator guide</p>
<footer>RayWn2App operator guide · RF StateSide LLC<br>Shared with the application’s offline Help. <a href="LICENSE">LGPL-3.0-only</a></footer></main><dialog id="image-dialog" aria-label="Help illustration"><div class="zoom"><button id="out" aria-label="Zoom out">−</button><button id="in" aria-label="Zoom in">+</button><button id="actual">100%</button><button id="fit">Fit</button><span id="percent"></span><button id="close">Close</button></div><div id="image-scroll"><img id="enlarged" alt=""></div></dialog></body></html>